AnonSec Team
Server IP : 10.2.73.233  /  Your IP : 216.73.216.59
Web Server : Apache/2.4.59 (Debian)
System : Linux polon 4.19.0-27-amd64 #1 SMP Debian 4.19.316-1 (2024-06-25) x86_64
User : www-data ( 33)
PHP Version : 5.6.40-64+0~20230107.71+debian10~1.gbp673146
Disable Function : pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,
MySQL : ON  |  cURL : ON  |  WGET : ON  |  Perl : ON  |  Python : ON
Directory (0755) :  /etc/sane.d/

[  Home  ][  C0mmand  ][  Upload File  ]

Current File : //etc/sane.d/plustek.conf
# Plustek-SANE Backend configuration file
# For use with LM9831/2/3 based USB scanners
#

# each device needs at least two lines:
# - [usb] vendor-ID and product-ID
# - device devicename
# i.e. for Plustek (0x07B3) UT12/16/24 (0x0017)
# [usb] 0x07B3 0x0017
# device /dev/usbscanner
# or
# device libusb:bbb:ddd
# where bbb is the busnumber and ddd the device number
# make sure that your user has access to /proc/bus/usb/bbb/ddd
#
# additionally you can specify some options
# warmup, lOffOnEnd, lampOff
#
# For autodetection use
# [usb]
# device /dev/usbscanner
#
# or simply
# [usb]
#
# or if you want a specific device but you have no idea about the
# device node or you use libusb, simply set vendor- and product-ID
# [usb] 0x07B3 0x0017
# device auto
#
# NOTE: autodetection is safe, as it uses the info it got
#       from the USB subsystem. If you're not using the
#       autodetection, you MUST have attached that device
#       at your USB-port, that you have specified...
#

[usb]

#
# options for the previous USB entry
#
# switch lamp off after xxx secs, 0 disables the feature
# (can also be set via frontend)
option lampOff 300

# warmup period in seconds, 0 means no warmup, -1 means auto-warmup
# (can also be set via frontend)
option warmup -1

# 0 means leave lamp-status untouched, not 0 means switch off
# on sane_close
# (can also be set via frontend)
option lOffOnEnd 1

#
# options to tweak the image start-position
# (WARNING: there's no internal range check!!!)
#
# for the normal scan area
#
option posOffX 0
option posOffY 0

# for transparencies
option tpaOffX 0
option tpaOffY 0

# for negatives
option negOffX 0
option negOffY 0

#
# for setting the calibration strip position
# (WARNING: there's no internal range check!!!)
# -1 means use built in
# (can also be set via frontend)
option posShadingY -1
option tpaShadingY -1
option negShadingY -1

#
# to invert the negatives, 0 disables the feature
#
option invertNegatives 0

#
# to disable the internal sensor speedup function, 
# 1 disables the feature
#
option disableSpeedup 0

#
# to save/restore coarse calibration data
# (can also be set via frontend)
option cacheCalData 0

#
# use alternate calibration routines
#
option altCalibration 0

#
# for skipping whole calibration step
#
option skipCalibration 0

#
# for skipping entire fine calibration step
# coarse calibration is done
#
option skipFine 0

#
# discard the result of the fine white calibration
#
option skipFineWhite 0

#
# some scanners have a dark calibration strip, in
# general this one should be used for calibration.
# As this could cause some trouble, this option
# overrides that and the dark calibration will be
# done by switching the lamp off
#
option skipDarkStrip 0

# for replacing the gain values found during coarse
# calibration
# (can also be set via frontend)
option red_gain   -1
option green_gain -1
option blue_gain  -1

# for replacing the offset values found during coarse
# calibration
# (can also be set via frontend)
option red_offset   -1
option green_offset -1
option blue_offset  -1

#
# for replacing the default lampoff settings, this
# works only for CIS devices like CanoScan LiDE20
# (can also be set via frontend)
option red_lampoff   -1
option green_lampoff -1
option blue_lampoff  -1

#
# for adjusting the default gamma values
# (can also be set via frontend)
option redGamma         1.0
option greenGamma       1.0
option blueGamma        1.0
option grayGamma        1.0

#
# to enable TPA (EPSON or UMAX, if autodetection fails)
# 0 means default behaviour as specified in the internal tables
# 1 means enable (needed for UMAX 3450)
option enableTPA 0

#
# model override functionality, currently only available for
# Mustek devices, using NSCs' vendor ID: 0x0400 and
# also their product ID: 0x1000 (LM9831) 0x1001 (LM9832)
#
# mov/PID    |    0x1000   |   0x1001
# ---------------------------------------
# 0 (default)| BearPaw1200 | BearPaw 2400
# 1          |   ignored   | BearPaw 1200
#
option mov 0

#
# and of course the device-name
#
# device /dev/usbscanner
device auto

#
# to define a new device, start with a new section:
# [usb] 
#

AnonSec - 2021